Electrical faults
Safety switch keeps tripping: causes and what to check
Most of the time it is an appliance. Sometimes it is water or the wiring. Here is how to tell which, without opening anything.
A safety switch, also called an RCD, trips when it detects electricity leaking out of a circuit to earth, which is what happens when current flows through a faulty appliance, through water, or through a person. When it keeps tripping, the most common cause is one faulty appliance. The next most common is moisture in something outdoors, and after that a fault in the fixed wiring.
You can safely find out which of those it is in most cases by unplugging appliances and resetting the switch once. If it still trips with everything unplugged, the fault is in the wiring or a fixed appliance, and that is a job for an electrician.
Is it dangerous?
An RCD tripping is the protection working. The fault it is reacting to can be dangerous, so stop and get help if any of these apply:
- You smell burning, see smoke or scorch marks, or a power point or the switchboard feels warm. Switch off at the main switch if safe, and call 000 if there is fire.
- Anyone felt a tingle or shock before it tripped. Leave the circuit off and do not use the appliance involved again.
- It trips the instant you reset it, every time, with everything unplugged.
- There is water near the switchboard, a power point or a light fitting.
What you can safely check
None of this involves opening anything:
- Note what happened. What was running, the time of day, and whether it rained. Write it down. The pattern is often the answer.
- Unplug everything on the part of the house that lost power. Kettles, toasters, heaters, fridges, washing machines and outdoor equipment are the usual suspects.
- Reset the RCD once. If it stays on, plug appliances back in one at a time, switching each on. If it trips when one particular appliance goes on, that appliance is the likely cause. Stop using it and get it checked or replaced.
- If it trips with everything unplugged, leave it off. The fault is in the fixed wiring or something permanently connected, such as an oven, hot water system, pool pump or air conditioner.
- Press the test button on each RCD every few months. If one does not trip when you press it, that device needs looking at.
What usually causes it
A faulty appliance
Anything with a heating element can develop a small leak to earth as it ages: kettles, toasters, ovens, heaters, dishwashers and washing machines. Fridges and freezers are another common one, which is why a trip overnight with nobody using anything often points at the fridge.
Moisture outdoors
Trips that come with rain, sprinklers or the morning dew point outside. Outdoor power points with failed weatherproofing, garden lights, external light fittings, pool equipment and cable joints in the ground all let water in over time.
Small leaks adding up
On older boards, one RCD often protects many circuits. Each appliance leaks a tiny amount, and together they can push the RCD over its limit with no single fault to find. The fix there is splitting the circuits across more protection, which is part of a switchboard upgrade.
Wiring faults and failing devices
Damaged cable insulation, pest damage in the roof, a nail through a cable, or an ageing RCD that has become oversensitive. These need testing with an instrument to find.
What an electrician does
- Asks you about the pattern: when, how often, and what was running.
- Tests the RCD itself for trip time and trip current, so we know whether the device is faulty or doing its job.
- Isolates the circuits behind it one at a time to find which one carries the fault.
- Tests the insulation on that circuit to find where the leak is, then traces it to the fitting, cable or appliance.
- Repairs it at a fixed price agreed once the cause is known, and tells you what it actually was.
That is how our fault finding works: hourly to find it, the rate told up front, then a fixed price for the fix.
If you are selling or renting the house, there are also WA rules on how many RCDs protect the circuits. See WA smoke alarm and RCD rules for sale and rental homes.
When to call
Call us if it trips with everything unplugged, if it trips with no pattern you can find, if it only trips in the rain, or if an RCD does not trip when you press its test button. Describe what happens through our contact page. We work 8:30am to 5pm, seven days. Outside those hours, leave the affected circuit off. If there is burning, smoke or a shock, switch off at the main switch if safe and call 000 for fire.
If it is the circuit breaker rather than the safety switch that keeps going off, read circuit breaker keeps tripping, because the causes are different.
FAQs
Questions on this
What is the difference between a safety switch and a circuit breaker?
A circuit breaker protects the cable from too much current. A safety switch, or RCD, watches for current leaking out of the circuit, for example through a person, and cuts the power very quickly when it finds it. One protects the wiring, the other protects people.
Why does my safety switch trip when it rains?
Water is getting into something on that circuit, usually an outdoor power point, garden lighting, an external light fitting or a cable joint. It is worth finding, because the same moisture that trips the RCD is a shock risk.
Can I just replace the safety switch?
Not yourself, and usually it is not the switch. In most cases the RCD is doing its job and the fault is elsewhere. We test the RCD and the circuits before replacing anything.
Is it OK to keep resetting it?
Reset it once. If it trips again straight away, or keeps tripping, leave it off and find the cause. An RCD that trips is reporting a fault, not causing one.
Get a quote
Still tripping and you cannot work out why?
Tell us when it trips and what else is running at the time. That pattern is the most useful clue we get.